<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-15 17-27-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
106.40 MHz 4/5, 72 dBuV SelectUK
Pilot RDS Phase Difference
7.6 kHz 3.3 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
9 kHz 53 kHz 1626 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,3 dBr 4,31 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SelectUK" C46F 15 (Other M) 1 0 1 5 17:27, 15.01.2026
RT
" "
AF EON
94.4, 99.3, 105.7 MHz -
FM Scope Max at: 53 kHz MIN: 9 kHz % above 76 kHz: 0,0000 Acquired: 2026/01/15 17.26.33 Total samples: 1626 Equivalent time: 0:01:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40 60
FM Scope MAX: 5,6 dBr MIN: 3,3 dBr AVE: 4,31 dBr % above 12,2 dBr: 0,0 Last value: 4,2 dBr (2026/01/15 17.26.33) 17.12 17.14 17.16 17.18 17.20 17.22 17.24 17.26 0 2 4 6 Pm [dBr]